Ethio Telecom in-building DAS
Keep-alive probes on every antenna of Ethio Telecom in-building DAS sites, with alarms sent to the ET NOC through a northbound API.
Keep-alive signal tracking for every antenna. A small probe at each antenna reports back through the existing feeders, so a break is found before complaints build up.
Probe fixed at the antenna tip
Probe sends its ID keep-alive.
Back through the existing DAS path.
Gateway at the head-end splitter.
Missing messages or falling levels.
Alarm sent northbound to the NOC.
The right team goes to the right point.
| What we see | Where the fault is | Who to send |
|---|---|---|
| One probe goes silent | That antenna, its jumper or connector | Technician to that antenna |
| All probes on one branch go silent | Splitter, coupler or trunk cable | RF engineer to that branch |
| All probes go silent at once | Head-end splitter or gateway | Check the equipment room first |
| A level drifts down over days | Connector, cable or water ingress | RF engineer with DTF / TDR tester |
Fault types detected at once
Seen as a trend against each probe's baseline
Left to existing NOC alarms, no overlap
Breaks seen before complaints; alarms name the antenna.
Right team to the right point; repair confirmed.
Feeders reused, one RF connection per building.
Coverage breaks found and fixed sooner.